![]() ![]() Date: 20-Apr-124 Transfer with Capillary TubePlain capillary tubes are recommended to transfer an aqueous control solution from the ampule to the cartridge. If necessary, tap the tip of the ampule to send solution back into the bottom section of the fingers with gauze, tissue or glove, or use an ampule breaker to snap off the tip of the ampule at the transfer the solution from the ampule into a capillary tube or syringe, and then immediately transfer the solution into a seal the cartridge and insert it into a handheld it is important not to expose the solution to room air since this will alter the results.ĥ Note: Since aqueous based solutions such as control materials lack the buffering capability of whole blood, the transfer process from ampule to cartridge must be more expedient than with a patient sample. The handheld allows 15 minutes (or the customized timeout) to insert the cartridge after the last data before use, shake the ampule vigorously for 5 to 10 seconds to equilibrate the liquid and gas shake, hold the ampule at the tip and bottom with forefinger and thumb to minimize increasing the temperature of the solution. ProcedureSTEPACTION1 Access the Control option under Quality Tests in the Administration Menu. If PO2 is not being measured, equilibrate the ampule for approximately 30 minutes at room temperature. However, cartridges without these sensors may be tested with remaining fluids if that Testing is performed within 10 minutes of opening the Usei-STAT TriControls solutions require different temperature stabilization times depending on whether or not PO2 is to be measured.Ĥ If PO2 is to be measured, equilibrate the ampule to room temperature for 4 hours prior to use. Date: 20-Apr-12 Best ResultsFor best results, ampules, cartridges and handhelds should be at the same UseWhen using cartridges that contain sensors for pH, PCO2, PO2 and ionized calcium, a separate ampule must be used for each cartridge being not use residual TriControls solution that may be in a syringe, ampule or capillary tube for additional Testing of cartridges that contain sensors for ionized calcium, pH, PCO2, or PO2. ![]() Do not use TriControls solutions past the labeled expiration date on the box and ampule Art: 723270-00A Rev. The control solutions do not contain human serum or serum products, but do contain buffers and Ingredients for TriControls MaterialsAnalyteCalibration Verification Level 1 Calibration Verification Level 2 and Control Level 1 Calibration Verification Level 3 and Control Level 2 Calibration Verification Level 4 and Control Level 3 Calibration Verification Level 5Na (mmol/L)97118124150159K (mmol/L) (mmol/L)677694119134 Glu (mg/dL)5952851606553 Urea (mg/dL) (mmol/L) (mmol/L) (mg/dL) (mmHg)9665402612PO2 (mmHg)4063120163500H+ (pH) storage at 2-8 C (35-46 F) should be maintained until the printed expiration date on the box and ampule labels.ģ TriControls solutions may also be maintained at room temperature (18-30 C 64-86 F) for up to 5 days. i-STAT TriControls Level 1, 2 and 3 are formulated at three clinically relevant levels with defined pH and hematocrit values and with known concentrations of:SodiumPCO2 GlucosePotassiumPO2 LactateChlorideTCO2 BUN/UreaIonized CalciumCreatinineEach level of control is packaged in a box containing 10 individual mL glass ampules. Date: 20-Apr-122 CONTROLS FOR BLOOD GAS/ELECTROLYTE/METABOLITE CARTRIDGES (i-STAT TriControls )Control SolutionsAqueous-based control fluids are available for verifying the integrity of newly received cartridges. Abbott List NumberDevice Name05P71-01 TriControls Control Level 105P72-01 TriControls Control Level 205P73-01 TriControls Control Level 305P70-01 TriControls Calibration Verification Set Levels 1-5 Art: 723270-00A Rev. This enables reduced control Testing in cases where all of these tests are being evaluated and : The additive used to simulate the effect of hematocrit results in reduced precision.Ģ Refer to the Precision section at the end of this document for additional details. Date: 20-Apr-12 TECHNICAL BULLETINi-STAT TriControlsControl Materials for Liquid QC and Calibration VerificationOVERVIEWAs part of the READi initiative (Responds, Enhances, And Delivers innovations), Abbott Point of Care (APOC) has released a new set of aqueous control and calibration verification materials that combine the ability to assay hematocrit, blood gases, electrolytes, and chemistries.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |